Almost parallel crimping die movement
Repetitive, high crimping quality due to precision dies and integral lock (self-releasing mechanism)
Crimping pressure has been set precisely (calibrated) in the factory, re-adjustable
Optimum transmission of force due to lever action for fatigue-reduced operation
Ergonomically designed handles
Different locators for precise positioning of the connectors
Crimping dies for applications not covered in the range offered here, may be available on request
Chrome vanadium electric steel in special quality, oil-hardened
Comes in a plastic case; foam insert with recesses for crimping dies and locators; with service tool (Allen wrench), screws and nuts; without crimping dies
Article No. | Pliers | Handles | Applications | Mm² | AWG | Crimping Positions | ||||
---|---|---|---|---|---|---|---|---|---|---|
97 43 200 | 200 | burnished | with multi-component grips | see crimping dies table | 988 | |||||
97 43 05 | 200 | burnished | with multi-component grips | Crimp System Pliers for non-insulated open plug-type connectors (4.8 and 6.3 mm connector width) | 0.5 - 6.0 | 20 - 10 | 3 | 618 | ||
97 43 06 | 200 | burnished | with multi-component grips | Crimp System Pliers for insulated terminals and plug connectors | 0.5 - 6.0 | 20 - 10 | 3 | 610 |
Article No. | Applications | Mm² | AWG | SW mm | Ø mm | Number of Crimping Positions | ||
---|---|---|---|---|---|---|---|---|
97 49 04 | non-insulated Plug Connectors | 0.1 - 2.5 | 27 - 13 | 4 | 42 | |||
97 49 05 | non-insulated Plug Connectors | 0.5 - 6.0 | 20 - 10 | 3 | 46 | |||
97 49 06 | insulated terminals and plug connectors | 0.5 - 6.0 | 20 - 10 | 3 | 45 | |||
97 49 08 | End Sleeves (ferrules) | 0.25 - 6.0 | 23 - 10 | 5 | 49 | |||
97 49 09 | End Sleeves (ferrules) | 10 / 16 / 25 | 7 / 5 / 3 | 3 | 50 | |||
97 49 13 | non-insulated terminals and plug connectors | 0.5 - 10.0 | 20 - 7 | 4 | 37 | |||
97 49 15 | lug connectors and non-insulated open plug type connectors (plug width 6.3 mm) | 1.25-2.5 + 3.0-6.0 | 17-13 + 12-9 | 2 + 1 | 56 | |||
97 49 16 | insulated terminals and plug connectors | 10.0 - 16.0 | 7 / 5 | 2 | 46 | |||
97 49 18 | Twin end sleeves (ferrules) for two flexible conductors | 2x6 / 10 / 16 | 10 / 7 / 5 | 3 | 48 | |||
97 49 19 | End Sleeves (ferrules) | 35 - 50 | 2 / 0 | 2 | 46 | |||
97 49 20 | F-connectors for TV and satellite connections | 7.0; 8.4; 8.1 | 7.7; 9.5; 9.5 | 3 | 50 | |||
97 49 23 | non-insulated terminals and plug connectors | 16 + 25 | 5 + 3 | 2 | 45 | |||
97 49 24 | D Sub; HD 20; HDE plug | 0.03 - 0.56 | 32 - 20 | 3 | 41 | |||
97 49 30 | non-insulated butt connectors | 1.5 - 4.0; 6.0 + 10.0 | 15 - 11; 10 + 7 | 3; 2 | 37 | |||
97 49 35 | spark plug connectors and distributors | 1 | 17 | 5 | 52 | |||
97 49 40 | Coax connectors RG 58, 59, 62, 71, 223 | 5.4; 6.48; 1.72 | 6.4; 7.6; 2.1 | 3 | 57 | |||
97 49 44 | rolled contacts | 0.14 - 1.5 | 26 - 15 | 3 | 45 | |||
97 49 50 | Coax connectors / Car phone RG 58, 174, 188, 316 | 3.25; 4.52; 5.41; 1.72; 1.07 | 3.9; 5.4; 6.4; 2.1; 1.3; 0.95 | 6 | 48 | |||
97 49 54 | modular plugs | 0.5 - 2.5 | 20 - 13 | 4 | 49 | |||
97 49 59 | solar cable connectors Helios H4 (Amphenol) | 2.5 + 4.0 + 6.0 | 13 - 10 | 3 | 35 | |||
97 49 60 | turned contacts (HTS + Harting) | 0.14 - 4.0 | 26 - 11 | 4 | 53 | |||
97 49 62 | solar cable connectors (Huber + Suhner) | 2.5 + 4.0 | 13 + 11 | 3 | 41 | |||
97 49 63 | solar cable connectors (Huber + Suhner) | 4.0 + 6.0 | 11 + 10 | 3 | 33 | |||
97 49 64 | ABS connectors | 1.0 - 6.0 | 17 - 10 | 2 | 73 | |||
97 49 65 | solar cable connectors MC3 (Multi-Contact) | 2.5 - 6.0 | 13 - 10 | 3 | 33 | |||
97 49 66 | solar cable connectors MC4 (Multi-Contact) | 2.5 - 6.0 | 13 - 10 | 3 | 33 | |||
97 49 66 4 | solar cable connectors MC4 (Multi-Contact): cuttings, stripping, crimping | 4.0 | 11 | 1 | 35 | |||
97 49 66 6 | solar cable connectors MC4 (Multi-Contact): cuttings, stripping, crimping | 6.0 | 10 | 1 | 35 | |||
97 49 67 | solar cable connectors (Hirschmann) | 2.5 - 6.0 | 13 - 10 | 3 | 33 | |||
97 49 68 | solar cable connectors (Tyco) | 1.5 - 6.0 | 15 - 10 | 4 | 33 | |||
97 49 69 1 | solar cable connectors (Wieland) | 1.5 - 2.5 | 15 + 13 | 2 | 35 | |||
97 49 69 2 | solar cable connectors (Wieland) | 4.0 - 10.0 | 11 - 7 | 3 | 35 | |||
97 49 70 | Western plugs | 4, 6, 8-poles RJ 10 / 11 / 12 / 45 | 3 | 72 | ||||
97 49 74 | unshielded Molex plugs | 4, 6, 8-poles RJ 10 / 11 / 12 / 45 | 3 | 42 | ||||
97 49 76 | shielded Stewart plugs | 2 | 50 | |||||
97 49 81 | Harting connectors for fibre optics | 3.0; 4.95; 6.5 | 3.5; 6.0; 7.5 | 3 | 52 | |||
97 49 82 | Telegartner connectors for fibre optics | 3.25; 3.65; 4.52 | 3.6; 4.0; 5.4 | 3 | 58 | |||
97 49 83 | F-SMA, ST-,SC + STSC/K-connectors for fibre optics | 3.65; 4.2; 5.0 | 4.3; 5.4; 6.0 | 3 | 60 | |||
97 49 84 | Harting/Suhner connectors for fibre optics | 3.8; 4.3; 4.95 | 4.5; 5.2; 6.0 | 3 | 52 | |||
97 49 87 | F-SMA, ST and MIC connectors for fibre optics | 8.7 | 9.5 | 1 | 46 |
For warranty service contact Knipex Tools LP or your nearest authorized Knipex dealer.
Warranty claims require return of the defective tool, proof of purchase, and confirmation from you that you are the original end-user purchaser of the tool. All shipping and transportation costs are excluded from this warranty.
THIS WARRANTY IS KNIPEX-WERK'S AND KNIPEX TOOLS LP'S SOLE WARRANTY FOR ITS TOOLS, AND IS IN LIEU OF ALL OTHER WARRANTIES AND CONDITIONS, EXPRESSED OR IMPLIED. KNIPEX-WERK and KNIPEX TOOLS LP DISCLAIMS ALL OTHER EXPRESS OR IMPLIED WARRANTIES AND CONDITIONS, INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABLE QUALITY, MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE.
Knipex-Werk and Knipex Tools LP neither assumes, nor authorizes any person to assume for it, any other warranty, condition, or obligation expressed or implied.